Technical Insights · 3 MIN READ

Robot Compliance Units: Offset, Angular Error, Stiffness and Insertion Depth

Understand why nominal floating travel does not establish insertion capability, and separate approach alignment, contact correction, seating and return behaviour.

Need help selecting? Send photos of the model, nameplate and installation; quantity may be unknown.

A compliance unit allows specified movement between the robot and tool so contact can help align an assembly. Its effectiveness depends on which directions can move, how much force causes that movement and where the compliance acts relative to the contact point.

Circular compliance unit with its two mounting interfaces and working gap visible.
Review both mounting interfaces and the permitted compliance directions before choosing an insertion unit.

Separate parallel offset from angular error

Parallel axes can be laterally displaced by a nearly constant amount. With angular error, separation changes along the engaged length. In a simple geometric example, one degree of angular error over 50 mm corresponds to about 0.87 mm of lateral difference, using length multiplied by the tangent of the angle.

That calculation does not predict an insertion's allowable error. Chamfers, clearances, friction, stiffness and part shape also matter. It shows why a pin can enter a short lead-in and still bind deeper in the hole.

PropertyPhysical meaningQuestion for the exact unit
Lateral travelPermitted translation across the tool axisWhich directions and under what load?
Angular travelPermitted tilt or rotationIs this movement provided or constrained?
StiffnessForce or moment needed for displacementIs contact force acceptable for the part?
Compliance centreRelationship between force and resulting movementWhere is it relative to the insertion point?
Recentering or lockingBehaviour between contact eventsDoes the tool return or hold as required?

Enough travel can still mean too much contact force

For an approximately linear direction, force change is stiffness multiplied by displacement. Two units with equal travel can therefore produce different lateral forces at the same offset. A low-stiffness arrangement may reduce contact load but also require review of stability and recentering.

ATI's remote-centre compliance description explains how compliance near the insertion point can assist alignment, and distinguishes lateral from angular stiffness. That principle does not establish the movements available on ANT ACM10 or AFC20-XY. Confirm each candidate's drawing and load data rather than inferring its behaviour from a circular housing or product name.

Inspect four phases separately

PhaseEvidence to observePossible issue to investigate
ApproachTool position before contactInitial offset, angle or residual displacement
First contactDirection and amount of corrective movementInadequate allowed direction or excessive stiffness
Deeper engagementInsertion force and travel usedAngular error, two-point contact or reaching a stop
Withdrawal and returnRelease behaviour and final neutral positionBinding, friction or incomplete recentering

Record tool length and part geometry with those observations. Moving the contact farther from the unit can change the force–motion relationship. A test using a short pin may therefore say little about a longer production component.

A compliance unit also cannot repair an incorrect tolerance stack or replace a missing locating feature. Define which errors it is expected to accommodate and which should be removed by the fixture or robot alignment. Validate representative tolerance combinations using the process owner's force and acceptance criteria.

Keep the installed orientation, tool length, unit settings and accepted test conditions with the assembly drawing. The useful result is a bounded correction capability for that assembly, not a general statement that the tool floats.

Product and technical references

ATI remote-center compliance principles Catalog source for the example

Read the field selection guide

Need help selecting? Send photos of the model, nameplate and installation; quantity may be unknown.