Robot Compliance Units: Offset, Angular Error, Stiffness and Insertion Depth
Understand why nominal floating travel does not establish insertion capability, and separate approach alignment, contact correction, seating and return behaviour.
Need help selecting? Send photos of the model, nameplate and installation; quantity may be unknown.
A compliance unit allows specified movement between the robot and tool so contact can help align an assembly. Its effectiveness depends on which directions can move, how much force causes that movement and where the compliance acts relative to the contact point.

Separate parallel offset from angular error
Parallel axes can be laterally displaced by a nearly constant amount. With angular error, separation changes along the engaged length. In a simple geometric example, one degree of angular error over 50 mm corresponds to about 0.87 mm of lateral difference, using length multiplied by the tangent of the angle.
That calculation does not predict an insertion's allowable error. Chamfers, clearances, friction, stiffness and part shape also matter. It shows why a pin can enter a short lead-in and still bind deeper in the hole.
| Property | Physical meaning | Question for the exact unit |
|---|---|---|
| Lateral travel | Permitted translation across the tool axis | Which directions and under what load? |
| Angular travel | Permitted tilt or rotation | Is this movement provided or constrained? |
| Stiffness | Force or moment needed for displacement | Is contact force acceptable for the part? |
| Compliance centre | Relationship between force and resulting movement | Where is it relative to the insertion point? |
| Recentering or locking | Behaviour between contact events | Does the tool return or hold as required? |
Enough travel can still mean too much contact force
For an approximately linear direction, force change is stiffness multiplied by displacement. Two units with equal travel can therefore produce different lateral forces at the same offset. A low-stiffness arrangement may reduce contact load but also require review of stability and recentering.
ATI's remote-centre compliance description explains how compliance near the insertion point can assist alignment, and distinguishes lateral from angular stiffness. That principle does not establish the movements available on ANT ACM10 or AFC20-XY. Confirm each candidate's drawing and load data rather than inferring its behaviour from a circular housing or product name.
Inspect four phases separately
| Phase | Evidence to observe | Possible issue to investigate |
|---|---|---|
| Approach | Tool position before contact | Initial offset, angle or residual displacement |
| First contact | Direction and amount of corrective movement | Inadequate allowed direction or excessive stiffness |
| Deeper engagement | Insertion force and travel used | Angular error, two-point contact or reaching a stop |
| Withdrawal and return | Release behaviour and final neutral position | Binding, friction or incomplete recentering |
Record tool length and part geometry with those observations. Moving the contact farther from the unit can change the force–motion relationship. A test using a short pin may therefore say little about a longer production component.
A compliance unit also cannot repair an incorrect tolerance stack or replace a missing locating feature. Define which errors it is expected to accommodate and which should be removed by the fixture or robot alignment. Validate representative tolerance combinations using the process owner's force and acceptance criteria.
Keep the installed orientation, tool length, unit settings and accepted test conditions with the assembly drawing. The useful result is a bounded correction capability for that assembly, not a general statement that the tool floats.
Product and technical references
ATI remote-center compliance principles Catalog source for the example
Read the field selection guide
Need help selecting? Send photos of the model, nameplate and installation; quantity may be unknown.