Selecting a Robot Compliance Unit for Insertion and Assembly
Separate lateral offset from angular error, then check available movement, restoring behaviour and tool loading. Includes enquiry and first-trial checklists for ACM10 and AFC20-XY candidates.
Need help selecting? Send photos of the model, nameplate and installation; quantity may be unknown.
A compliance unit allows specified relative movement between the robot and tooling so a suitable assembly process can accommodate limited misalignment. It does not replace a stable fixture, correct approach path or dimensional control of the parts. Identify the mismatch before selecting a device.

Locate the error at the point of insertion
Consider a pin approaching a bore. The pin may be laterally displaced, tilted, or both. Record those errors at the mating feature, together with insertion depth, lead-in geometry and the distance from the robot flange to the tool tip. A small angular error can produce a different tip displacement when the tool length changes.
ATI's remote-centre compliance description explains controlled accommodation around a designed compliance centre. Use it to understand the principle, not to assign ATI performance to an ANT part. Ask the selected manufacturer to define its own supported directions, centre location and limits.
| Process observation | Information needed | Selection question |
|---|---|---|
| Parallel but offset pin and bore | Lateral scatter at the entry | Does the unit allow the required lateral movement? |
| Tilted pin | Angular error and tool length | Is angular accommodation available and where is its centre? |
| Tool must travel in a repeatable pose | Transport loads and sequence | Is centering or locking needed, and is it fitted? |
| Part catches during insertion | Lead-in, depth and contact-force limit | Does the proposed compliance suit this geometry? |
Treat the catalogue names as candidates
The ACM10 precision compensation unit and AFC20-XY floating unit are listed for enquiries. An XY designation identifies a direction concept, not proof of angular compliance, sensor inclusion or usable travel under your load. Request the full variant specification and assembly drawing.
Describe tool mass and centre of gravity, robot acceleration and process forces. Ask about restoring force, allowed movement and the conditions under which those values apply. Do not infer load capacity from the diameter of the flange or from the size of the visible gap.
Plan a trial that can expose the limits
Provide representative parts at the intended tolerance extremes. Agree what counts as successful seating, acceptable contact force and reliable recentering. Have the integrator use the machine's approved commissioning procedure and stop criteria; increasing insertion force is not a substitute for understanding a jam.
Check the release and withdrawal sequence as well as insertion. A tool that seats once but does not recenter consistently can create problems on the next approach. If the process changes tool length or fixture revision, review whether the original compliance configuration still applies.
| Enquiry attachment | Ask the supplier to confirm |
|---|---|
| Part and fixture drawings | Applicable misalignment accommodation |
| Measured offset, tilt and insertion depth | Usable movement and compliance-centre assumptions |
| Tool mass, length and load case | Allowable loading and restoring behaviour |
| Transport and insertion sequence | Locking, centering and sensing options |
| Acceptance requirements and quantity | Exact variant, accessories and trial scope |
Keep the selected unit code, tool geometry and accepted trial conditions together. That record is more useful for repeat purchases than the general description “floating compensator.” Use Discuss your requirements to submit the mating geometry and observed scatter.
Product and technical references
ATI remote-center compliance principles Catalog source for the example
Need help selecting? Send photos of the model, nameplate and installation; quantity may be unknown.