Dress-Pack Mounting Bases: Hole Spacing, Stand-Off and the Mechanical Load Path
See why a base that bolts into place can still alter conduit alignment, leverage and wrist clearance. Use interface and symptom tables to evaluate a replacement.
Need help selecting? Send photos of the model, nameplate and installation; quantity may be unknown.
A mounting base connects the robot or adapter to a conduit holder. Hole spacing checks only part of that connection. The seating plane, locating features, installed height and holder orientation determine where the bundle runs and how its forces reach the robot structure.

Trace the force through both interfaces
The holder transfers a load into the base, which transfers it into the robot-side mounting. A force acting away from the mounting plane creates a moment. For a perpendicular force, the simplified relationship is M = F × e, with force F and perpendicular offset e.
For illustration, a 30 N side force at a 50 mm offset produces 1.5 N·m. Moving the same force to 80 mm produces 2.4 N·m. Neither value is a rating for a catalogue base. The example explains why adding a spacer or using a taller substitute changes the mounting load even if the bolts still fit.
| Feature | Mechanical role | Consequence of a mismatch |
|---|---|---|
| Seating plane | Supports and orients the base | Rocking, tilt or local contact stress |
| Hole pattern and thread | Secures the joint | Wrong engagement or incompatible hardware |
| Pins, shoulders or slots | Establishes position or adjustment | Rotation or loss of a repeatable datum |
| Installed height | Positions the holder and load path | Changed leverage and bend entry |
| Upper seat and retention | Locates the actual holder | Incorrect fit or restricted intended motion |
Height and orientation also change the cable route
A different stand-off can shift the point where the conduit begins to bend. A rotated holder may force the tube to enter the next support at an angle. The base can therefore be mechanically secure while creating a new contact point or reducing clearance at a folded wrist position.
Check dimensions from a common datum, including the adapter if one is fitted. Comparing two drawings with different reference faces can hide an offset. Use the complete assembled envelope rather than a photograph of an isolated part to assess interference.
The TYSEM 0317DZ-048 and 0317DZ-070 codes identify different catalogue families. They do not by themselves establish interchangeable bolt patterns, stiffness or permitted motion. Request the exact base and holder drawings when those properties matter.
Read the evidence before changing the mounting
| Observation | Question to investigate | Useful record |
|---|---|---|
| Conduit rubs immediately after the holder | Has the entry angle or free span changed? | Side view at the affected pose |
| Mounting loosens repeatedly | Is the joint seating correctly and carrying the intended load? | Joint drawing, fastener specification and maintenance findings |
| Replacement only fouls at folded positions | Has height or orientation changed the swept envelope? | Critical-pose clearance check |
| Holder moves within the base | Is the seat or retention arrangement correct? | Exact mating codes and wear inspection |
Do not assign a tightening torque from the bolt diameter alone; the approved joint specification must account for its materials and arrangement. After an authorised change, record the base code, adapter, orientation and mounting procedure together. A hole-spacing measurement without that context is not a complete compatibility record.
Product and technical references
HELU dress-pack components Catalog source for the example
Read the field selection guide
Need help selecting? Send photos of the model, nameplate and installation; quantity may be unknown.